36000 BTU Quad Zone Ductless Mini Split Air Conditioner Heat Pump: 9000

x 4

USD $2,899.00

Condition : New

Free Shipping

{{variant_type_name}} :
eBay
SKU: T322D-H236-09X4 This site contains affiliate links for which we may be compensated Home & Garden / Home Improvement / Heating, Cooling & Air / Central Heating & Cooling Systems / Ductless Mini Split Systems

Notify me when the price drops

We will email you if we find a lower price on this product!

Target price (USD) $
Thermocore 36000 BTU AC-Heat 22 SEER

36000 BTU Quad Zone Energy Star Mini Split AC
22 SEER Efficiency w/ Heat Pump Technology
With a 36000 BTU total Cool / Heat Capacity, the Thermocore T7HH25D-H236 9+9+9+9 mini split AC can cool or heat 4 separate zones of 9000 BTU for a total coverage area of 1600 ft² (4 x 400 ft²).  Operation temps down to -22F as well as maximum energy efficiency. 4 x 25ft Install kits included. 1 Year Part - 5 year compressor warranty.  Pre-charged with R454B for 100ft of Refrigerant


Technical Data:
System Includes:
  • 36000 BTU INVERTER Cooling Capacity (9+9+9+9)
  • 36000 BTU INVERTER Heating Capacity (9+9+9+9)
  • 23 SEER - 10 HSPF - AHRI / ENERGY STAR Eligible*
  • Pre-Charged with R454B for 100ft of total lineset
  • 1 Year Parts - 5 Year Compressor Warranty View Details >

  • Indoor Unit - Air Handler.
  • Outdoor Unit - Condenser of 36000 BTUs
  • Digital Multi-function LCD Remote Control.
  • Installation Kit with 25' x 4 of lineset. >>>
  • Product and Installation Manual. >>>
 
Top Line Features:
  • 22 SEER - 11 HSPF - ENERGY STAR
  • Dry-Mode removes moisture w/o affecting temp
  • Cross Flow Technology reduces noise output
  • Pre-charged with R454B Refrigerant for 100ft
  • Compatible with over 5 Filtration medias
  • Freon Leak Detection > Notification system
  • Low Ambient Temperature Operation (-22° F)
  • Two-direction Air vane Evenly Distributes Air
  • Restart IC: Settings restored Following Outage
  • Follow-Me Function tracks Remote Location



Capacity 9000 BTU Air Flow (Hi/M/Lo) 440/380/260 cfm Power Supply 230 V / 60 Hz / 1Ph Noise Output (Hi/M/Lo) 43/37/31 dBA Liquid / Gas 1/4" x 3/8" Weight 17.6 lbs Dimensions (W x D x H) 32.9" × 7.8" × 11" inches

Model Number T7HH23D-H236-C Compressor Brand TOSHIBA - GMCC Capacity 27000-33000 BTU Maximum AHU Capacity 48000 BTU Air Flow 2148 CFM Power Supply 230 V / 60 Hz / 1Ph Fuse Size 30A SEER 23 EER 12 HSPF4 10 Sound Level 61 dBA Operating Temp Range -22 F to 122 F (cool and heat) Refrigerant R454B / 121oz Charge Liquid / Gas 1/4" x 3/8" (3) + 1/4" x 1/2" (1) Max Lineset Length (1 zone) 114 ft Max Lineset Length (all zones) 263 ft Pre-Charge Length 100 ft (25 ft x 4) Weight 168.4 lbs Dimensions (W x D x H) 37.24 × 16.14 × 32 inches

Install Kit Contents:
  • 25 Feet Flared Copper Tubing x 4
  • 25 Feet Pipe Insulation x 4
  • 25 Feet Electrical Wire x 4
  • Drain Pipe (outdoor)
  • Outdoor Condenser Rubber pads
  • Wall Bracket for Indoor Unit x 4
  • Brass Adaptors for Alternate lineset sizes
  • Installation and User Manuals

*** Extend 15 foot copper lineset to 25-30-40-50-65 feet. Just $4.50 / additional foot*** contact us for details >



WHAT IS DC INVERTER?

DC Inverter Air Conditioners are the ultimate cooling technology of the HVAC field. They are called "DC inverter" because the alternative current (AC) is converted to Direct Current (DC) then, direct current inverted back to Alternative current with desired frequency. The current supplied through the wall outlet has fixed frequency which is 60 Hertz. Different frequencies supplied to the compressor will result in different running speeds of the compressor. Inverter control systems use Pulse Amplitude Modulation (PAM) that is the most advanced and energy efficient method of inverting the current. DC Inverter AC's bear special compressors that their speed could be changed by increasing or decreasing the frequency of the supplied power. Therefore, unlike conventional split Air Conditioners Pumps which cycle between on and off repeatedly, the DC Inverter control system will monitor the room temperature and adjust the compressor speed automatically.

Conventional compressors turn on and off to maintain the room temperature at desired level. This will result compressor to draw tremendous energy each time it starts up. This will also reduce the life-span of the compressor and other components that are turning on and off. Once a conventional system is running, it runs at its maximum speed, consuming the maximum amount of energy in order to produce the maximum of cooling to maintain the desired temperature. The system will then cycle between on and off in an effort to maintain this temperature. When a DC Inverter compressor initially starts up, it runs with a higher speed to bring the room temperature to desired level rapidly, Once the set temperature is reached, it slows down and adjust its capacity just to counter the heat loss or heat gain of the building. Constant temperature is maintained.









BASIC OVERVIEW: The indoor unit is hung like a picture frame approximately 6 - 8 feet above the floor usually on an exterior wall. A 2-3 inch hole must be made behind the indoor unit in the exterior wall to run the refrigerant copper tubing, electrical wires and the condensate drain to the outside unit. The indoor unit and outdoor unit are connected to each other by means of refrigerant copper tubing and electrical cables. The condensing unit comes pre-charged with R454B however, procedures such as conducting leak tests etc. are still important steps in ensuring proper functioning of a split AC. *Although installation may seem easy to some, certain tools and experience is necessary to complete setup of a mini split* Click for Installation Tip. It is highly advised a certified HVAC technician complete installation to be eligible for warranty. See warranty details below >







*5 Year Compressor - 1 Year on all other Parts* Registration card will be sent with unit, this card should be completed by an HVAC technician (installer). Installation of a mini split must be completed by a licensed HVAC (Heating, ventilating, & air conditioning) company to ensure any issues encountered in the future are not due to improper installation / workmanship. Even though mini split setup is below the expertise requirements of central AC systems, these are not "plug-n-play" units that can be properly installed without certain tools any prior HVAC - electrical knowledge. The installation includes electrical, gas, and refrigerant connections and generally regulated by a multiple sets of laws, codes and guidelines, at the federal, state and local levels. The failure to properly install HVAC equipment can raise personal safety and performance concerns. Warranty service - troubleshooting is provided through the contractor / installer and will be upheld as long as policies are observed. Once a non-defective unit is installed by a HVAC company, chances of anything going wrong are very slim and almost all contractors will guarantee there workmanship and provide future service free of charge (installation warranty). If it was determined that the unit is not functioning due to a defect and needs to be replaced, the part will be sent free of charge up to 1 year from date of purchase or 5 years for the compressor. If you receive a damaged or defective product, a replacement unit will be sent out Free of cost. Damaged / Defective product will be picked up and a brand new exchange will be shipped out. 1 YEAR PARTS WARRANTY CAN BE EXTENDED TO 2 YEARS FOR AN ADDITIONAL $72.00

36000 BTU Quad Zone Ductless Mini Split Air Conditioner Heat Pump: 9000 x 4
quad
See more
Price type
IN STOCK OUT STOCK